- Blown film air cooler
- Water cooled blown film air cooler
- Air cooled blown film cooling fan
- Precision variable frequency blown film air cooler
- Industrial air cooler
- Industrial Chiller
- Air-cooled chiller
- Water-cooled chiller
- Water-cooled screw machine
- Precision variable frequency chiller
- Corrosion resistant chiller
- Foam constant temperature chiller
- Oil temperature cooler
- Non standard refrigeration equipment
DC-LF30A-T industrial air cooler
Performance Characteristic
★ The post air cooler uses its point-to-point cooling method to deliver low-temperature cold air (10-25 ℃) to high-temperature areas and equipment, blowing away hot air and bringing coolness. Save the high investment and electricity consumption of installing air conditioning throughout the entire workshop; Improve the working environment for operators in high-temperature areas, enhance employee efficiency, and reduce employee turnover.
Application scope
Widely used in metallurgy, power generation, machinery, printing, injection molding and other high heat generating and densely populated production workshops to cool down worker positions.
Model | DC-LF3A | DC-LF5A | DC-LF10A-D | DC-LF15A-T | DC-LF20A-F | DC-LF25A-F | DC-LF30A-T | DC-LF40A-F | DC-LF50A-F | |
Horsepower HP | HP | 3 horses | 5 horses | 10 horses | 15 horses | 20 horses | 25 horses | 30 horses | 40 horses | 50 horses |
Refrigeration capacity | kcal/h | 7181 | 12900 | 25800 | 38700 | 51600 | 64500 | 77400 | 103200 | 129000 |
KW | 8.35 | 15 | 30 | 45 | 60 | 75 | 90 | 120 | 150 | |
Air outlet temperature control ℃ | 10-25℃ | |||||||||
Power supply | 380V 50HZ 3PH(Special voltage can be customized) | |||||||||
Refrigerant | R22(Optional refrigerant R407C, R410A) | |||||||||
Condenser | Air cooled condenser (copper tube wrapped in corrugated aluminum foil for heat dissipation) | |||||||||
Fan | Type | High air volume, low-noise external rotor fan | ||||||||
Air volume | m³/h | 1200 | 2000 | 4000 | 6000 | 7500 | 9000 | 12000 | 15000 | 20000 |
Evaporator | Copper tube aluminum foil finned evaporator | |||||||||
Appearance Size |
Length D mm | 955 | 1105 | 1255 | 1800 | 1910 | 2098 | 2098 | 2148 | 2158 |
Width W mm | 655 | 650 | 805 | 1050 | 1100 | 1248 | 1248 | 1248 | 2108 | |
Height H mm | 1230 | 1232 | 1737 | 1750 | 1890 | 2186 | 2178 | 2159 | 2530 | |
Protection control device | High and low voltage protection, overheating, antifreeze, phase sequence, overload, water shortage protection, etc |
1. Selection Description: DC-LF10A-D "DC" Multi Library Company Code, "LF" represents blown film air cooler, "10" represents 10 horsepower, "A" represents air-cooled, "W" represents water-cooled, "D" has 2 compressors in a dual system, and "T" has 3 compressors.
2. The cooling capacity parameters are based on: cold air inlet and outlet temperature of 35 ℃/10 ℃, and condensation temperature of 35 ℃.
3. Scope of work: Cold air outlet temperature of 10-25 ℃, ambient temperature below 40 ℃.
4. Our company reserves the right to change the above parameters or dimensions without prior notice.
2. The cooling capacity parameters are based on: cold air inlet and outlet temperature of 35 ℃/10 ℃, and condensation temperature of 35 ℃.
3. Scope of work: Cold air outlet temperature of 10-25 ℃, ambient temperature below 40 ℃.
4. Our company reserves the right to change the above parameters or dimensions without prior notice.