- Blown film air cooler
- Water cooled blown film air cooler
- Air cooled blown film cooling fan
- Precision variable frequency blown film air cooler
- Industrial air cooler
- Industrial Chiller
- Air-cooled chiller
- Water-cooled chiller
- Water-cooled screw machine
- Precision variable frequency chiller
- Corrosion resistant chiller
- Foam constant temperature chiller
- Oil temperature cooler
- Non standard refrigeration equipment
DC-RC80W-BP precision fully variable frequency chiller
Performance Characteristic
★ The water-cooled screw chiller adopts Taiwan's "Hanzhong" twin-screw compressor, refrigeration accessories such as Danfoss and Emerson, with high overall efficiency, stable performance, and long service life. The touch screen and PLC control system accurately control the energy regulation of the compressor, which can timely and accurately control the matching between the cooling capacity and heat load of the unit, ensuring the unit operates with high efficiency and reducing operating costs. Full Chinese operation interface, menu style prompts, and the ability to freely set the operating status of the unit; The built-in hydraulic system ensures that the compressor maintains its lubrication effect. Efficient internally threaded copper tube enhances heat transfer efficiency and saves energy; The U-shaped heat exchange tube bundle facilitates maintenance and prevents refrigerant leakage; High efficiency, low noise, and low vibration.
★ Customizable variable frequency precision screw chiller, with a temperature control accuracy of ± 0.5 ℃ for chilled water. Accurate temperature control meets the chilled water requirements of precision equipment and saves energy by more than 15-20%.
Model | DC-RC40W-BP | DC-RC50W-BP | DC-RC60W-BP | DC-RC80W-BP | DC-RC100W-BP | DC-RC120W-BP | DC-RC140W-BP | DC-RC160W-BP | DC-RC180W-BP | DC-RC200W-BP | DC-RC240W-BP | DC-RC280W-BP | |
Horsepower | HP | 40 horses | 50 horses | 60 horses | 80 horses | 100 horses | 120 horses | 140 horses | 160 horses | 180 horses | 200 horses | 240 horses | 280 horses |
Refrigeration capacity | kcal/h | 123960 | 162625 | 176954 | 258769 | 323523 | 384963 | 457968 | 531271 | 598349 | 698537 | 801296 | 878543 |
KW | 145 | 191 | 206 | 296 | 383 | 452 | 536 | 617 | 699 | 783 | 904 | 1026 | |
Total input power | 32 | 38 | 46 | 61 | 75 | 92 | 99 | 116 | 139 | 143 | 169 | 197 | |
Temperature range ℃ | 7-25℃ | ||||||||||||
Power supply | 380V 50HZ 3PH(Customizable special voltage 220/410/460V 50/60HZ) | ||||||||||||
Refrigerant | R22(Optional refrigerant R407C, R410A) | ||||||||||||
Condenser | Type | Shell and tube type | |||||||||||
Cooling water volume(m³/h) | 32 | 40 | 44 | 63 | 79 | 95 | 110 | 128 | 147 | 156 | 188 | 211 | |
Inlet and outlet pipe diameter (inches) | 3” | 3” | 4” | 4” | 4” | 5” | 5” | 5” | 6" | 6” | 6” | 6” | |
Evaporator | Type | Shell and tube dry evaporator (optional stainless steel plate heat exchanger) | |||||||||||
Frozen water volume(m³/h) | 35 | 43 | 52 | 68 | 85 | 105 | 120 | 136 | 153 | 170 | 205 | 238 | |
Inlet and outlet pipe diameter (inches) | 3” | 3” | 3” | 4” | 4” | 5” | 5” | 5” | 6” | 6” | 6” | 6” | |
Appearance Size |
Length D mm | 1970 | 2210 | 2480 | 2925 | 3570 | 3810 | 4190 | 4230 | 4330 | 4510 | 4630 | 4880 |
Width W mm | 860 | 875 | 991 | 998 | 1100 | 1100 | 1150 | 1370 | 1400 | 1400 | 1580 | 1800 | |
Height H mm | 1550 | 1550 | 1680 | 1680 | 1680 | 1790 | 1790 | 1790 | 1820 | 1820 | 1930 | 1930 | |
Unit weight(KG) | 840 | 960 | 1140 | 1510 | 1750 | 2040 | 2270 | 2480 | 2680 | 2860 | 3150 | 3380 | |
Safety protection | Compressor overheat protection, unit overload protection, refrigerant high and low pressure protection, antifreeze protection device, overcurrent protection, phase sequence and phase loss protection, overload protection, over temperature protection, etc |
Technical description
1. Selection Description: DC-RC50W "DC" is the company code of Duoku. "RC" represents screw chiller, "50" represents horsepower 50, "W" represents water-cooled, and "BP" represents variable frequency.
2. The cooling capacity parameters are based on: chilled water inlet and outlet temperatures of 12 ℃/7 ℃, and cooling inlet and outlet air temperatures of 30 ℃/35 ℃.
3. Scope of work: The temperature range of the chilled water is 7 ℃ to 25 ℃, and the temperature difference between the inlet and outlet of the chilled water is 3 ℃ to 8 ℃. The operating environment temperature cannot exceed 40 ℃, and high-temperature models should be selected if the ambient temperature is higher than 40 ℃.
4. Our company reserves the right to change the above parameters or dimensions without prior notice.
2. The cooling capacity parameters are based on: chilled water inlet and outlet temperatures of 12 ℃/7 ℃, and cooling inlet and outlet air temperatures of 30 ℃/35 ℃.
3. Scope of work: The temperature range of the chilled water is 7 ℃ to 25 ℃, and the temperature difference between the inlet and outlet of the chilled water is 3 ℃ to 8 ℃. The operating environment temperature cannot exceed 40 ℃, and high-temperature models should be selected if the ambient temperature is higher than 40 ℃.
4. Our company reserves the right to change the above parameters or dimensions without prior notice.
Application
![]() |
![]() |
![]() |
![]() |